{"id":1590,"date":"2023-07-21T17:49:42","date_gmt":"2023-07-21T08:49:42","guid":{"rendered":"https:\/\/lintec-mfc.co.jp\/en\/?page_id=1590"},"modified":"2024-03-06T14:26:19","modified_gmt":"2024-03-06T05:26:19","slug":"accessory","status":"publish","type":"page","link":"https:\/\/lintec-mfc.co.jp\/en\/home\/accessory\/","title":{"rendered":"Mass Flow Controller Power Supply|Vaporizer Temperature Controller"},"content":{"rendered":"\n<p>Connection examples of Lintec products and various accessories required to use Lintec products (mass flow controllers, vaporizers, heat exchangers).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><a href=\"https:\/\/lintec-mfc.co.jp\/en\/accessory\/rp-310\/\">Power Supply\/Read-Out Unit for MFC [RP-310<\/a>]<\/h2>\n\n\n\n<p class=\"epb-margin-top__8\">By connecting one Lintec mass flow controller and one Power Supply\/Read-Out Unit for MFC (RP-310) with a dedicated cable, it is possible to set and read out the flow rate (both current and totalized) via analog communication.<\/p>\n\n\n\n<div class=\"wp-block-columns epb-margin-top__8 is-layout-flex wp-container-3\">\n<div class=\"wp-block-column is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading\">Examples of Use<\/h3>\n\n\n\n<ul>\n<li>Sensible MFC flow rate setting with potentiometer<\/li>\n\n\n\n<li>Stand-alone MFC flow control<\/li>\n\n\n\n<li>Display of the totalized flow rate of the MFC<\/li>\n\n\n\n<li>Flow control of MFC in both local and remote modes (host PLC)<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/lintec-mfc.co.jp\/en\/accessory\/rp-310\/\"><img decoding=\"async\" loading=\"lazy\" width=\"293\" height=\"264\" src=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/Power-supply-Read-out-Unit-2-in-1.png\" alt=\"Mass Flow Controller\u3000Power supply Read-out Unit 2 in 1\" class=\"wp-image-1592\"\/><\/a><figcaption class=\"wp-element-caption\">Power supply Read-out Unit 2 in 1<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><a href=\"https:\/\/lintec-mfc.co.jp\/en\/accessory\/ps\/\">Power supply unit for MFC [PS Series]<\/a><\/h2>\n\n\n\n<p class=\"epb-margin-top__8\">By using the power supply unit (PS Series), which can connect up to 9 mass flow controllers, multiple MFCs can be controlled by a PC, PLC, or other means.<\/p>\n\n\n\n<div class=\"wp-block-columns epb-margin-top__8 is-layout-flex wp-container-6\">\n<div class=\"wp-block-column is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading epb-margin-top__8\">Examples of Use<\/h3>\n\n\n\n<ul>\n<li>Power supply for MFC digital control from a PC (e.g. LabVIEW)<\/li>\n\n\n\n<li>Power supply for MFC control from a PLC<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/lintec-mfc.co.jp\/en\/accessory\/ps\/\"><img decoding=\"async\" loading=\"lazy\" width=\"324\" height=\"286\" src=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/Power-supply-only.png\" alt=\"Mass Flow Controller\u3000Power supply only\" class=\"wp-image-1591\" srcset=\"https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/Power-supply-only.png 324w, https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/Power-supply-only-300x265.png 300w\" sizes=\"(max-width: 324px) 100vw, 324px\" \/><\/a><figcaption class=\"wp-element-caption\">Mass Flow Controller\u3000Power supply only<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><a href=\"https:\/\/lintec-mfc.co.jp\/en\/accessory\/im-10\/\">MFC in-line monitor [IM-10]<\/a><\/h2>\n\n\n\n<p class=\"epb-margin-top__8\">By connecting an in-line monitor (IM-10) between the mass flow controller and the equipment power supply, input signals, output signals, valve open\/close signals, and power supply voltage voltages are measured. The operation of the mass flow controller can be checked inline.<\/p>\n\n\n\n<div class=\"wp-block-columns epb-margin-top__8 is-layout-flex wp-container-9\">\n<div class=\"wp-block-column is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading\">Examples of Use<\/h3>\n\n\n\n<ul>\n<li>Check supply voltage (\u00b115V) to MFC<\/li>\n\n\n\n<li>Check the MFC flow rate setting value (0 to 5V)<\/li>\n\n\n\n<li>Check the MFC flow output value (0 to 5V)<\/li>\n\n\n\n<li>Check the MFC valve open\/close signal<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/lintec-mfc.co.jp\/en\/accessory\/im-10\/\"><img decoding=\"async\" src=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/IM-10.png\" alt=\"\" class=\"wp-image-1594\"\/><\/a><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><a href=\"https:\/\/lintec-mfc.co.jp\/en\/home\/accessory\/tcu\/\">Temperature Control Unit [TCU Series]<\/a><\/h2>\n\n\n\n<p class=\"epb-margin-top__8\">Temperature control unit provides power supply and allows temperature adjustment for Lintec heat exchangers (HX series), liquid vaporizers (VU series), or other products that require temperature control.<\/p>\n\n\n\n<div class=\"wp-block-columns epb-margin-top__8 is-layout-flex wp-container-12\">\n<div class=\"wp-block-column is-layout-flow\" style=\"flex-basis:40%\">\n<h3 class=\"wp-block-heading epb-margin-top__8\">Examples of Use<\/h3>\n\n\n\n<ul>\n<li>Temperature Control of Heat Exchangers (HX Series)<\/li>\n\n\n\n<li>Temperature control of vaporizers (VU Series)<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow\" style=\"flex-basis:70%\">\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/lintec-mfc.co.jp\/en\/home\/accessory\/tcu\/\"><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/Connection-Diagram-for-Temperature-Control-Unit.png\" alt=\"Connection Diagram for Temperature Control Unit]\" class=\"wp-image-1593\" width=\"695\" height=\"313\" srcset=\"https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/Connection-Diagram-for-Temperature-Control-Unit.png 695w, https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/Connection-Diagram-for-Temperature-Control-Unit-300x135.png 300w\" sizes=\"(max-width: 695px) 100vw, 695px\" \/><\/a><figcaption class=\"wp-element-caption\">Connection Diagram for Temperauter Control Unit<\/figcaption><\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Connection examples of Lintec products and various accessories required to use Lintec products (mass flow cont [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":4,"menu_order":5,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/1590"}],"collection":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/comments?post=1590"}],"version-history":[{"count":9,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/1590\/revisions"}],"predecessor-version":[{"id":2373,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/1590\/revisions\/2373"}],"up":[{"embeddable":true,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/4"}],"wp:attachment":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/media?parent=1590"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}