{"id":135,"date":"2016-12-01T16:18:45","date_gmt":"2016-12-01T07:18:45","guid":{"rendered":"http:\/\/ae1371jxuo.smartrelease.jp\/?page_id=135"},"modified":"2024-03-04T10:51:20","modified_gmt":"2024-03-04T01:51:20","slug":"ps","status":"publish","type":"page","link":"https:\/\/lintec-mfc.co.jp\/en\/home\/accessory\/ps\/","title":{"rendered":"Power Supply Unit for MFC[PS Series]"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-3\">\n<div class=\"wp-block-column is-layout-flow\">\n<p>PS series power supply supports max. 9 MFC units and provides \u00b115 power supply, which is necessary for most mass flow controllers and meters.<\/p>\n\n\n\n<p>The power supply can handle a wide range of voltages from AC85 to 240V, and external control is also possible by relaying mass flow setting signals, output signals, and valve open\/close signals.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"519\" height=\"400\" src=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/PS\u30b7\u30ea\u30fc\u30ba.jpg\" alt=\"Power supplies dedicated to mass flow controllers [PS Series]\" class=\"wp-image-1988\" srcset=\"https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/PS\u30b7\u30ea\u30fc\u30ba.jpg 519w, https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/PS\u30b7\u30ea\u30fc\u30ba-300x231.jpg 300w\" sizes=\"(max-width: 519px) 100vw, 519px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Connection example<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-6\">\n<div class=\"wp-block-column is-layout-flow\">\n<h3 class=\"wp-block-heading\">Analog Communications<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/\u7121\u984cp.jpg\" alt=\"\" class=\"wp-image-1999\" width=\"368\" height=\"201\" srcset=\"https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/\u7121\u984cp.jpg 508w, https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/\u7121\u984cp-300x164.jpg 300w\" sizes=\"(max-width: 368px) 100vw, 368px\" \/><\/figure>\n\n\n\n<p>Flow setting signals and flow output signals are input to the mass flow controller from a host device such as a PLC via the PS series, and a \u00b115 V power supply is supplied from the PS series.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow\">\n<h3 class=\"wp-block-heading\">Digital Communications<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"532\" height=\"278\" src=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/PS-\u30c7\u30b8\u30bf\u30eb.jpg\" alt=\"\" class=\"wp-image-2000\" srcset=\"https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/PS-\u30c7\u30b8\u30bf\u30eb.jpg 532w, https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/PS-\u30c7\u30b8\u30bf\u30eb-300x157.jpg 300w\" sizes=\"(max-width: 532px) 100vw, 532px\" \/><\/figure>\n\n\n\n<p>When using a PC interface such as LabVIEW or a digital communication from a PLC to prevent the noise, the PS series supplies a power of \u00b115V to the mass flow controller.<\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Specification sheet<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Model<\/td><td>PS-203M<\/td><td>PS-206M<\/td><td>PS-209M<\/td><\/tr><tr><td>Number of MFC connections<\/td><td>3 units<\/td><td>6 units<\/td><td>9 units<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-file\"><object class=\"wp-block-file__embed\" data=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/PS-Series.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"PS Series\u306e\u57cb\u3081\u8fbc\u307f\u3002\"><\/object><a id=\"wp-block-file--media-27efb9de-f2e7-4cec-80cc-ca74f697c3f9\" href=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/PS-Series.pdf\">PS Series<\/a><a href=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/PS-Series.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-27efb9de-f2e7-4cec-80cc-ca74f697c3f9\">Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>PS series power supply supports max. 9 MFC units and provides \u00b115 power supply, which is necessary for most ma [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1590,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/135"}],"collection":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/comments?post=135"}],"version-history":[{"count":10,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/135\/revisions"}],"predecessor-version":[{"id":2345,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/135\/revisions\/2345"}],"up":[{"embeddable":true,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/1590"}],"wp:attachment":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/media?parent=135"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}