{"id":102,"date":"2016-12-01T16:05:36","date_gmt":"2016-12-01T07:05:36","guid":{"rendered":"http:\/\/ae1371jxuo.smartrelease.jp\/?page_id=102"},"modified":"2024-03-25T11:51:03","modified_gmt":"2024-03-25T02:51:03","slug":"lm-3000l","status":"publish","type":"page","link":"https:\/\/lintec-mfc.co.jp\/en\/mass-flow-controller\/liquid\/lm-3000l\/","title":{"rendered":"High Performance Mass Flow Meter"},"content":{"rendered":"\n<p>A high-performance digital mass flow meter for liquids with a built-in microflow rate sensor and PID controller.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-3\">\n<div class=\"wp-block-column is-layout-flow\">\n<h2 class=\"wp-block-heading\">LM-3000L Series<\/h2>\n\n\n\n<p>LM-3000L is equipped with a high precision liquid flow sensor, achieving high accuracy micro flow rate measurement of liquids with 0.1g\/min to 20g\/min full scale equivalent to C2H5OH.<\/p>\n\n\n\n<p>Since it has a built-in PID controller, it is possible to control the flow rate of liquid by combining it with Lintec\u2019s valve-equipped products (<a href=\"https:\/\/lintec-mfc.co.jp\/en\/liquid-vaporization\/vaporizer\/#Atomizing-vaporizers\" title=\"\"><span class=\"epb-underline\">vaporizers<\/span><\/a>, <a href=\"https:\/\/lintec-mfc.co.jp\/en\/mass-flow-controller\/liquid\/cv-1000\/\" title=\"\"><span class=\"epb-underline\">control valves<\/span><\/a>).<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow\">\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/LM-3000L.jpg\" alt=\"High Performance Digital Mass Flow Meter\nLM-3000L Series\" class=\"wp-image-1860\" width=\"229\" height=\"300\" srcset=\"https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/LM-3000L.jpg 305w, https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/LM-3000L-229x300.jpg 229w\" sizes=\"(max-width: 229px) 100vw, 229px\" \/><figcaption class=\"wp-element-caption\">LM-3000L<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-6\">\n<div class=\"wp-block-column is-layout-flow\">\n<h3 class=\"wp-block-heading\"><span data-color=\"#ff6900\" class=\"vk_highlighter\" style=\"background: linear-gradient(transparent 60%,rgba(255, 105, 0, 0.7) 0);\">Feature<\/span><\/h3>\n\n\n\n<ul class=\"epb-margin-top__8\">\n<li>Micro flow liquid measurement<\/li>\n\n\n\n<li>Vaporization flow control<\/li>\n\n\n\n<li>Accuracy \u00b11% F.S.<\/li>\n\n\n\n<li>Metal seal<\/li>\n\n\n\n<li>Clean (zero particle structure)<\/li>\n\n\n\n<li>RS-485 communication<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow\">\n<h3 class=\"wp-block-heading\"><span data-color=\"#0693e3\" class=\"vk_highlighter\" style=\"background: linear-gradient(transparent 60%,rgba(6, 147, 227, 0.7) 0);\">Option<\/span><\/h3>\n\n\n\n<ul>\n<li>High temperature<\/li>\n\n\n\n<li>Sterile processing (SPI) treatment<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Examples of Use<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Flow control of liquid vaporization flow rate<\/h4>\n\n\n\n<p class=\"epb-margin-top__8\">By combining a liquid mass flow meter (LM-3000L) with a Lintec\u2019s vaporizer with built-in control valve (<a href=\"https:\/\/lintec-mfc.co.jp\/en\/liquid-vaporization\/vaporizer\/#Atomizing-vaporizers\" title=\"\"><span class=\"epb-underline\">VU<\/span><\/a>), it is possible to control the flow rate introduced into the vaporizer in the immediate vicinity of the vaporization chamber. Therefore, a highly responsive vaporization flow control is achieved without being affected by the heat of the vaporizer.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Liquid flow control<\/h4>\n\n\n\n<p class=\"epb-margin-top__8\">Since LM-3000L has a built-in PID controller, it can be used as a mass flow controller when used with a Lintec control valve (<a href=\"https:\/\/lintec-mfc.co.jp\/en\/mass-flow-controller\/liquid\/cv-1000\/\" title=\"\"><span class=\"epb-underline\">CV-1000<\/span><\/a>).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Specification Table<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Model<\/th><th class=\"has-text-align-center\" data-align=\"center\">LC-3112L<\/th><th class=\"has-text-align-center\" data-align=\"center\">LC-3212L<\/th><th class=\"has-text-align-center\" data-align=\"center\">LC-3712L<\/th><\/tr><\/thead><tbody><tr><td>Flow rate C2H5OH conversion<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1 \uff5e 1.0g\/min<\/td><td class=\"has-text-align-center\" data-align=\"center\">\uff5e 6g\/min<\/td><td class=\"has-text-align-center\" data-align=\"center\">\uff5e 30g\/min<\/td><\/tr><tr><td>Flow rate H2O conversion<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1 \uff5e 0.2g\/min<\/td><td class=\"has-text-align-center\" data-align=\"center\">\uff5e 1.0g\/min<\/td><td class=\"has-text-align-center\" data-align=\"center\">\uff5e 15g\/min<\/td><\/tr><tr><td>Accuracy<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">1.0% F.S.<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.0% F.S.<\/td><\/tr><tr><td>Operating differential pressure<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">50 \uff5e 300kPa<\/td><\/tr><tr><td>Temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">15 \uff5e 35\u2103<\/td><\/tr><tr><td>Seal materials<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Au<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-file\"><object class=\"wp-block-file__embed\" data=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/LM-3000L-Series.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"LM-3000L Series\u306e\u57cb\u3081\u8fbc\u307f\u3002\"><\/object><a id=\"wp-block-file--media-0be57c82-311b-4334-afba-f41d5a2473a4\" href=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/LM-3000L-Series.pdf\">LM-3000L Series<\/a><a href=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/LM-3000L-Series.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-0be57c82-311b-4334-afba-f41d5a2473a4\">Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>A high-performance digital mass flow meter for liquids with a built-in microflow rate sensor and PID controlle [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":36,"menu_order":4,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/102"}],"collection":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/comments?post=102"}],"version-history":[{"count":16,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/102\/revisions"}],"predecessor-version":[{"id":2542,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/102\/revisions\/2542"}],"up":[{"embeddable":true,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/36"}],"wp:attachment":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/media?parent=102"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}