{"id":100,"date":"2016-12-01T16:05:09","date_gmt":"2016-12-01T07:05:09","guid":{"rendered":"http:\/\/ae1371jxuo.smartrelease.jp\/?page_id=100"},"modified":"2024-03-25T11:51:36","modified_gmt":"2024-03-25T02:51:36","slug":"lc-3000l","status":"publish","type":"page","link":"https:\/\/lintec-mfc.co.jp\/en\/mass-flow-controller\/liquid\/lc-3000l\/","title":{"rendered":"High Performance Digital Mass Flow Controller"},"content":{"rendered":"\n<p>A high performance digital liquid mass flow controller combining a built-in piezo actuator with the liquid mass flow sensor.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-3\">\n<div class=\"wp-block-column is-layout-flow\">\n<h2 class=\"wp-block-heading\">LC-3000L Series<\/h2>\n\n\n\n<p>A liquid mass flow controller which integrates a thermal liquid flow rate sensor and a high precision piezo actuator valve.<\/p>\n\n\n\n<p>By measuring the current mass flow rate with a liquid mass flow sensor and controlling the opening degree of the piezo valve with the feedback, it is possible to automatically control the liquid mass flow rate at high speed.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow\">\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/LC-3000L.jpg\" alt=\"High Performance Digital Mass Flow Controller\nLC-3000L Series\" class=\"wp-image-1858\" width=\"229\" height=\"300\" srcset=\"https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/LC-3000L.jpg 305w, https:\/\/ld7wbevg6gkl.cdn.shift8web.com\/en\/wp-content\/uploads\/2023\/07\/LC-3000L-229x300.jpg 229w\" sizes=\"(max-width: 229px) 100vw, 229px\" \/><figcaption class=\"wp-element-caption\">LC-3000L<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-6\">\n<div class=\"wp-block-column is-layout-flow\">\n<h3 class=\"wp-block-heading\"><span data-color=\"#ff6900\" class=\"vk_highlighter\" style=\"background: linear-gradient(transparent 60%,rgba(255, 105, 0, 0.7) 0);\">Feature<\/span><\/h3>\n\n\n\n<ul class=\"epb-margin-top__8\">\n<li>Micro flow liquid control<\/li>\n\n\n\n<li>Accuracy \u00b11% F.S.<\/li>\n\n\n\n<li>Clean (zero particle structure)<\/li>\n\n\n\n<li>RS-485 communication<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Example of Use<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Continuous control of micro flow rate without pulsation<\/h4>\n\n\n\n<p class=\"epb-margin-top__8\">Although metering pumps are convenient products that can flow a fixed amount of liquid, due to the moving parts they are subject to pulsation. Lintec\u2019s liquid mass flow controllers are capable of stable flow control without pulsation as long as they are pressurized at an appropriate and constant pressure.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Liquid Control to Vacuum Equipment<\/h4>\n\n\n\n<p class=\"epb-margin-top__8\">If a metering pump is applied for flow control under downstream vacuum conditions, liquid tends to escape, making it hard to control the flow control. The liquid mass flow controller (LC-3000 series), which integrates a control valve and mass flow sensor, can control the flow rate regardless of the secondary pressure as long as the specified differential pressure conditions are met.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Specification Table<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Model<\/th><th class=\"has-text-align-center\" data-align=\"center\">LC-3102L<\/th><th class=\"has-text-align-center\" data-align=\"center\">LC-3202L<\/th><th class=\"has-text-align-center\" data-align=\"center\">LC-3702L<\/th><\/tr><\/thead><tbody><tr><td>Flow rate C2H5OH conversion<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1 \uff5e 1.0g\/min<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.0 \uff5e 2.0g\/min<\/td><td class=\"has-text-align-center\" data-align=\"center\">\uff5e 30g\/min<\/td><\/tr><tr><td>Flow rate H2O conversion<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1 \uff5e 0.2g\/min<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.2 \uff5e 0.4g\/min<\/td><td class=\"has-text-align-center\" data-align=\"center\">\uff5e 15g\/min<\/td><\/tr><tr><td>Flow rate control range<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">5\uff5e100% F.S.<\/td><td class=\"has-text-align-center\" data-align=\"center\">10\uff5e100% F.S.<\/td><\/tr><tr><td>Valve operation mode<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Normally open<\/td><td class=\"has-text-align-center\" data-align=\"center\">Normally closed<\/td><\/tr><tr><td>Flow rate control range<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">5\uff5e100% F.S.<\/td><td class=\"has-text-align-center\" data-align=\"center\">10\uff5e100% F.S.<\/td><\/tr><tr><td>Operating differential pressure<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">50 \uff5e 300kPa<\/td><\/tr><tr><td>Temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\">15 \uff5e 35\u2103<\/td><td class=\"has-text-align-center\" data-align=\"center\">20 \uff5e 30\u2103<\/td><td class=\"has-text-align-center\" data-align=\"center\">15 \uff5e 35\u2103<\/td><\/tr><tr><td>Seal materials<\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\">Au<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-file\"><object class=\"wp-block-file__embed\" data=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/LC-3000L-Series.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"LC-3000L Series\u306e\u57cb\u3081\u8fbc\u307f\u3002\"><\/object><a id=\"wp-block-file--media-20ebc411-835f-4f95-8062-d6f7ec56f2ad\" href=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/LC-3000L-Series.pdf\">LC-3000L Series<\/a><a href=\"https:\/\/lintec-mfc.co.jp\/en\/wp-content\/uploads\/2023\/07\/LC-3000L-Series.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-20ebc411-835f-4f95-8062-d6f7ec56f2ad\">Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>A high performance digital liquid mass flow controller combining a built-in piezo actuator with the liquid mas [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":36,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/100"}],"collection":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/comments?post=100"}],"version-history":[{"count":16,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/100\/revisions"}],"predecessor-version":[{"id":2543,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/100\/revisions\/2543"}],"up":[{"embeddable":true,"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/pages\/36"}],"wp:attachment":[{"href":"https:\/\/lintec-mfc.co.jp\/en\/wp-json\/wp\/v2\/media?parent=100"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}